Stationary systems

AQUATOR

... they are "tailor-made" systems depending on the customers needs

Fuleda Park Sp z o.o. 300 m3/dobę uzdatnionej wody

AQUATOR - SAFE WATER.

The idea behind the creation of the Aquator system was born due to the deterioration of the quality of water intended for drinking. It concerns the protection of water quality in crisis situations caused by ecological disasters and failures as well as the increasing use of the water supply network.

The system can be used to treat water of various origins, such as wells, rivers, lakes, ground and underground water. It can also be used to improve the quality of tap water but it is not acceptable due to periodic exceedances of some acceptable norm values, stabilizing its parameters. It improves the taste and smell. The system protects against bacteriological contamination, chemical and radioactivity, guaranteeing the highest quality of drinking water.

It allows the use of a single-family house, a block of flats as well as a housing estate on every scale. It does not require additional infrastructure, it works automatically, in a flow.

The AQUATOR Water Treatment System is a series of devices that are applicable in the absence of basic water quality data or variable water quality.

The range of potentially hazardous substances to be removed (from drinking water).

Standard system:

  • Heavy metal cations (such as Fe iron, Mg manganese, Cu2 + copper, Ni2 + nickel, Pb2 + lead, etc., and specific toxicants, such as Hg2 + mercury, Cd2 + cadmium, Tl2 + tal, Ar3 As3 + arsenic and others).
  • Anions as nitrates NO3-, nitrites NO2-, PO4 phosphates, CrO42- chromates, CN- cyanides (also cyanide complexes with metal cations), AsO33- arsenites and AsO43- arsenates, S2- sulphides, and many others: inorganic as well as organic anions, such as PhO- phenolates, anions of R-SO3 anionic detergents, etc.
  • Harmful and dangerous microorganisms: bacteria, fungi, viruses, algae, protozoa, (also clostridia and
    cryptosporidium bacteria).

TYPE: STANDARD DEVICES:

1. Aquator 1.

  • efficiency: 1.0 m3 / h (nominal) 1.6 m3 / h (maximum),
  • mechanical filtration system (hand-operated filter or exchangeable cartridges),
  • 3 filters in a series, filter diameter: 8 "height 35",
  • UV lamp,
  • building area 2.5 m2.
  • Version only for water supply systems.

2. Aquator 2.

  • capacity: 2.4 m3 / h (nominal)  3.6 m3 / h (maximum),
  • mechanical filtration system (hand-operated filter or exchangeable cartridges),
  • 3 filters in a series, filter diameter 12 "height 54",
  • UV lamp,
  • building area 3.0 m2.
  • Version only for water supply systems.

3. Aquator 4

  • capacity: 4.0 m3 / h (nominal)  6.4 m3 / h (maximum),
  • mechanical filtration system (automatic),
  • 3 filters in series, filter diameter 16 "height 65",
  • UV lamp,
  • 5m2 building area.

4. Aquator 6

  • capacity: 6.5 m3 / h (nominal) 8.2 m3 / h (maximum),
  • mechanical filtration system (automatic),
  • 3 filters in series, filter diameter 18 "height 65",
  • UV lamp,
  • 6m2 building area.

5. Aquator 9

  • efficiency: 9.0 m3 / h (nominal)  14.4 m3 / h (maximum),
  • mechanical (automatic) filtration system,
  • 3 filters in a series of filter diameters 24 "height 69",
  • UV lamp,
  • building area 10 m2.

6. Aquator 16

  • capacity: 16.0 m3 / h (nominal)  25.6 m3 / h (maximum),
  • mechanical filtration system (automatic),
  • 3 filters in series, filter diameter 32 "height 72",
  • UV lamp,
  • building area of ​​15 m2.

7. Aquator 20

  • capacity: 20.0 m3 / h (nominal)  32.4 m3 / h (maximum),
  • mechanical filtration system (automatic),
  • 3 filters in series, diameter 36 "height 72",
  • UV lamp,
  • building area of ​​15 m2.

EXTENDED EFFECTS OF EFFICIENCY:

It is possible to extend the system's efficiency range for special applications. If special requirements are required, the user must identify the contaminants to be eliminated from treated water. Because we have extensive knowledge about ion-exchange techniques as well as experience in individual chemical processes, solutions can be applied immediately, with the guarantee of their full effectiveness ..

This applies to both pollution loads as well as the location of the intake (surface water).

In this situation, we use attachments that meet "special tasks".

In the case of chemical contamination, it is an additional filter or filtration system (eg cesium trapping) or a pump system and mechanical filtration in the case of surface water or deep well power.